title: Why is the magnet in my Abort Gate not holding up the blade?
description: Troubleshooting guide for a faulty magnet in an abort gate. Covers potential issues like misaligned magnets and improper adjustments, providing step-by-step instructions for troubleshooting and corrections.
---

[Skip to content](https://kb.isystemsweb.com/knowledge/why-is-the-magnet-in-my-abort-gate-not-holding-up-the-blade#main-content)

English

Show submenu for translations

![Imperial Logo-01-2](https://kb.isystemsweb.com/hs-fs/hubfs/Imperial%20Logo-01-2.png?width=200&height=96&name=Imperial%20Logo-01-2.png)

Open main navigation

Close main navigation

- English
  
  Show submenu for translations
- Back to Imperial Systems

 Back to Imperial Systems

 We're here to help.

- There are no suggestions because the search field is empty.

1. [Solutions Database](https://kb.isystemsweb.com/knowledge?hsLang=en)
2. [Abort Gate](https://kb.isystemsweb.com/knowledge/abort-gate?hsLang=en)

# Why is the magnet in my Abort Gate not holding up the blade?

### Spark console not connected.

Verify that a spark detect console is connected between terminals 3 and 4.

### Magnet not aligned with striker plate.

Verify that the magnet is contacting the striker plate evenly. If there is any gap between the magnet and striker plate, the magnet will not hold.

### Magnet not adjusted properly.

Any fluctuations in the supply power will cause the abort gate to trip. If you have an abort gate that is tripping randomly, please verify that the line voltage to the abort gate is stable.

Verify that the magnets are adjusted properly. Follow the procedure below to properly adjust the magnets.

1. Disconnect the cord on the blade up proximity switch. The proximity switch is located on the top of the abort gate next to the magnet.
   
   ![proximity switch](https://kb.isystemsweb.com/hs-fs/hubfs/proximity%20switch.jpg?width=688&height=459&name=proximity%20switch.jpg)
2. Press and hold the raise gate button on the control panel until the actuator fully extend and comes to a hard stop with the blade fully extended.
3. On the magnet, adjust the 2 magnet hanger nuts so that the nut just touches the washer and you can spin the washer by hand.
   
   ![magnet hanger nuts](https://kb.isystemsweb.com/hs-fs/hubfs/magnet%20hanger%20nuts.jpg?width=688&height=459&name=magnet%20hanger%20nuts.jpg)
4. Reconnect the cable to the proximity switch. The actuator arm will retract and the abort gate will arm.

- [General Dust Collection](https://kb.isystemsweb.com/knowledge/general-dust-collection?hsLang=en#main-content)
  
  
  
  
  
    - [KST](https://kb.isystemsweb.com/knowledge/general-dust-collection?hsLang=en#kst)
- [CMAXX Dust & Fume Collector](https://kb.isystemsweb.com/knowledge/cmaxx-dust-fume-collector?hsLang=en)
- [BRF Baghouse Dust Collector](https://kb.isystemsweb.com/knowledge/brf-baghouse-dust-collector?hsLang=en#main-content)
  
  
  
  
  
    - [Medium Pressure Baghouse](https://kb.isystemsweb.com/knowledge/brf-baghouse-dust-collector?hsLang=en#medium-pressure-baghouse)
- [Spark Trap](https://kb.isystemsweb.com/knowledge/spark-trap?hsLang=en)
- [Abort Gate](https://kb.isystemsweb.com/knowledge/abort-gate?hsLang=en)
- [Air-Port Fume Exhaust Hood](https://kb.isystemsweb.com/knowledge/air-port-fume-exhaust-hood?hsLang=en)
- [Dust Collector Cartridge Filters](https://kb.isystemsweb.com/knowledge/dust-collector-cartridge-filters?hsLang=en)

[![Imperial Logo-01-2](https://kb.isystemsweb.com/hs-fs/hubfs/Imperial%20Logo-01-2.png?width=200&height=96&name=Imperial%20Logo-01-2.png "Imperial Logo-01-2")](http://isystemsweb.com)

Still need answers? Give us a call at 800-918-3013.