title: Why isn't the blower fan motor running on my CMAXX Dust & Fume Collector?
description: There are a handful of reasons that your blower fan motor may not be running. Let's break them down.
---

[Skip to content](https://kb.isystemsweb.com/knowledge/why-isnt-the-blower-fan-motor-starting-on-my-cmaxx-dust-fume-collector#main-content)

English

Show submenu for translations

![Imperial Logo-01-2](https://kb.isystemsweb.com/hs-fs/hubfs/Imperial%20Logo-01-2.png?width=200&height=96&name=Imperial%20Logo-01-2.png)

Open main navigation

Close main navigation

- English
  
  Show submenu for translations
- Back to Imperial Systems

 Back to Imperial Systems

 We're here to help.

- There are no suggestions because the search field is empty.

1. [Solutions Database](https://kb.isystemsweb.com/knowledge?hsLang=en)
2. [CMAXX Dust & Fume Collector](https://kb.isystemsweb.com/knowledge/cmaxx-dust-fume-collector?hsLang=en)

# Why isn't the blower fan motor running on my CMAXX Dust & Fume Collector?

## There are a handful of reasons that your blower fan motor may not be running. Let's break them down.

### My blower fan motor is not starting.

- **Improper motor wire size** - Rewire using the correct wire gauges as specified by national and local codes.
- **Motor not wired properly** - See motor manufacturer's wiring diagram. Check and correct motor wiring for the supply voltage present. Follow wiring diagram and the National Electric Code.
- **Motor not wired for available voltage** - Check the power supply to the motor circuit on all leads.
- **Input circuit down** - Check the power supply to the motor circuit on all leads.
- **Electrical supply circuit down** - check the power supply circuit for proper voltage. Check for any fuse or circuit breaker fault.

### My blower fan motor starts, but does not stay running.

- **Incorrect motor-starter installed** - Check for the proper motor starter and replace if necessary.
- **Blower fan damper control not adjusted properly** - Check airflow in duct. Adjust damper control until proper airflow is achieved and the blower motor's amp draw is within the manufacturer's rated amps.
- **Electrical circuit overload** - Check that power supply circuit has sufficient power to run all the equipment.

- [General Dust Collection](https://kb.isystemsweb.com/knowledge/general-dust-collection?hsLang=en#main-content)

    - [KST](https://kb.isystemsweb.com/knowledge/general-dust-collection?hsLang=en#kst)
- [CMAXX Dust & Fume Collector](https://kb.isystemsweb.com/knowledge/cmaxx-dust-fume-collector?hsLang=en)
- [BRF Baghouse Dust Collector](https://kb.isystemsweb.com/knowledge/brf-baghouse-dust-collector?hsLang=en#main-content)

    - [Medium Pressure Baghouse](https://kb.isystemsweb.com/knowledge/brf-baghouse-dust-collector?hsLang=en#medium-pressure-baghouse)
- [Spark Trap](https://kb.isystemsweb.com/knowledge/spark-trap?hsLang=en)
- [Abort Gate](https://kb.isystemsweb.com/knowledge/abort-gate?hsLang=en)
- [Air-Port Fume Exhaust Hood](https://kb.isystemsweb.com/knowledge/air-port-fume-exhaust-hood?hsLang=en)
- [Dust Collector Cartridge Filters](https://kb.isystemsweb.com/knowledge/dust-collector-cartridge-filters?hsLang=en)

[![Imperial Logo-01-2](https://kb.isystemsweb.com/hs-fs/hubfs/Imperial%20Logo-01-2.png?width=200&height=96&name=Imperial%20Logo-01-2.png "Imperial Logo-01-2")](http://isystemsweb.com)

Still need answers? Give us a call at 800-918-3013.

Copyright © 2025, Imperial Systems, Inc.